Reload to refresh your session. Saved searches Use saved searches to filter your results more quickly EDIT: It occurs to me that maybe you printed a retraction tower test with a fixed retraction value of 2. We are always looking for better ways. 7 ( never used this one i use orca slicer) and do flow calibration, advance pressure, Print temperature as an option i do maximum print speed test and retraction test and. This is a high value which should work first time but feel free to test this at lower values for yourself. foruonlyfrom007 June 26, 2023, 9:06pm 8. 265 nozzle temp. There are many options available online! Line Width: It often helps to increase the line width by a small. Sorry you’re having all sorts of issues, but for me. 6mm Nozzle Changes. 6. However there are some new options - Specifically Bambu Studio / Orca Slicer. Z lift is on, no wipe. link:Tech Github:Dans cette vidéo, je vous aide à installer Orca Slicer et à paramétrer votre première imprimante. You either can zip it, upload it to gdrive. Yes it is a advanced setting, but it is es setting. and not one that starts an 0mm on the bottom and ends at 2mm on the top. The only way I find is to add several extruders, change rectration settings for each one and later change something in the G-code to make one extruder again. . 6. For normal nozzles, the faster settings are good, so this is a specific case. that the Prusa wants, not the Bambu settings, unless you have a Bambu profile in your Prusa slicer. How does one set the retraction distance in Orca? I've found the setting for retraction speed but not the distance. I like to use vision minor adhesive or if you have tpu glue it helps. (which are the default Orca Slicer retraction test parameters) wootsuit July 23, 2023,. In Cura, you need to edit the Flow value. Filament - !!!Dry!!! as others suggested , and filament parameters especially if not using Bambu filament, strongly suggest to use Orca slicer 1. . . Please add a Test for tuning Retraction and DeRetraction Calibration (Extra restart) De-retraction is extra important when running with larger nozzles. Retraction distance: 2 mm. This is likely to make blobbing worse, not better. I am fairly sure the printer has nothing about retraction. Choose “Orca Tolerance Test”, then take a look at its X and Y distance, remember them down. Filament flow. In fact, while material profiles may be provided, specific spools can be somewhat chemically different, and thus it’s always a good idea to tweak settings when using new filament. E-18 is a retraction of 18mm (The minus sign IS important!) A retraction of 18mm should bring the filament clear of the melt zone. Scroll down until you get to the part called "Assets. already recalibrated everything via orca slicer and online video. Published Nov 20, 2023. r/klippers. Disable any vertical lift feature (such Z-Hop in Cura, a popular slicer). From 0 to 5mm height (it will make more sense later) Ret Speed Inc – Every 5 mm in height it will increase the speed this amount. The different towers all have the same shape and go from 180 to 220 °C for PLA. 61 on windows 10. 2 tasks done. 2mm, according to your machine spec extruder settings that you’ve shared, and not one that starts an 0mm on the bottom and ends at 2mm on the top. I believe that you can save. With respect to advertising, we and selected third parties, may use geolocation data and identification through device. In my testing when I only changed the retraction speed and distance I got the best results, the other settings seemed to make it worse. On the other hand, if there is still a lot of stringing at the top of the tower, it is recommended to dry your filament and ensure that your nozzle is properly installed without any leaks. (which are the default Orca Slicer retraction test parameters)Start with a small retraction length (in proportion to how long your bowden tube is), if in doubt start at 2mm. Tip: On some tpu filaments like 95A I will also run the retraction speed @ 100 mm/s and the. Also have seam issues with nearly everything I print. Retraction, along with print temperature, is the print. Any tips on where the defects are coming from and/or what direction to look at?Orca Slicer: All You Need to Know to Get Started. 2 reviews . Enable Cura retraction, enable Cura firmware retraction, set printer. 20mm Standard@FLSun V400 for print quality, select 'Preview' tab - all looks good. There are a number of test prints for this calibration step. I selected "Generic Klipper Printer 0. I found the ideal temperature for a specific filament on a single run of this test, which was slightly different from the manufacturer’s default setting. 2 steel nozzles. Happy printing!Test Prints – Speed Test. I recently tried out orcaslicer, and I love a lot of features they have, that Cura doenst have or less accessible. 1 of 2 tasks. Hello 3D Printing Friends! Here’s a quick, easy way to set up a Temperature Tower test model, using PrusaSlicer’s "Add Custom G-Code" feature!Smart Compact T. Bed temperature – 70℃. In this article, you can find my setting and how I. This is the only slicer I use now and it gives me almost 100 percent good prints. I really like Cura and its layout. If you haven’t checkout out Orca Slicer yet, it comes packed with many helpful calibrations that’ll help you get any filament dialed in. TL;DR: way more stringing in Orca slicer then in Cura, while using the same retraction settings. A nice touch would be able to do the calibration, on a smooth plate, with the LIDAR and then have some way to save the info or at least get the info out. 007. 4. Fix macOS deps build issues. Direct drive should be tested in increments of 0. To set up pressure advance in Klipper, you must first run some test prints and use these results to calculate the appropriate pressure advance value. Part 6, Orca Tolerance Test. • 1 mo. EDIT: It occurs to me that maybe you printed a retraction tower test with a fixed retraction value of 2. Adjust the printing parameters to get the best results for your 3D printer. The best way to determine your printer’s optimal settings is to look up and print a retraction test. (which are the default Orca Slicer retraction test parameters) Non uniform scaling of the source STL needs to occur to suit certain nozzle/layer combinations. There are fans of MatterControl and. These include the Sovol 3D Cura slicer as well as Cura itself. Bridge flow. (which are the default Orca Slicer retraction test parameters)3D Print Retraction Test. Read on to learn all about it! Advertisement. With option 2 you can use the tuning tower command to easily find the retraction settings that work for you. 8mm 45mm/s retraction. Part 6, Orca Tolerance Test. TL;DR: way more stringing in Orca slicer then in Cura, while using the same retraction settings. 19RockinRiley69. 0 mm at 30 to 45 mm/s have proven to be good starting values. 2. I think what he meant by "in slicer", you can set Klipper pressure advance command (same one used when you test) in filament profiles in slicer. File:13 Squareness. Retraction; One thing that could be optimized (in orca): the flowrate calculation is a bit "complicated" (I do it in Excel), this could be done in the UI with just adding the "value" from the test and then the software calculates it. If they don't you'll at least have a basis for what might be wrong. Filament - !!!Dry!!! as others suggested , and filament parameters especially if not using Bambu filament, strongly suggest to use Orca slicer 1. Bambu Slicer has a “compare presets” feature which is really cool, see the button in the photo below. Passing Slicer Variables to a Macro; Useful Macros. I'm using prusaslicer and i'm not touching slicers pressure advance, but i'm setting it FROM slicer > but really emitting to gcode as "start print gcode". Feb 27, 2023 · 0 comments Return to top. Orca Slicer 1. Next test - dehumidified filament - 5 hours 50 oC - light improvement - comparable with temperature increasing somewhere between 5-10 oC. These changes have made a big improvement but need to eliminate that swirl blob. 5) This was because I started printing TPU for the first time and it would ooze out while the printer went on to do it's other startup stuff. Retraction distance: 3 mm. adamfilipon Mar 4. Would be a great help if we could also print a test object and find the best retraction, wipe settings for a certain fixed temperature. Answered by SoftFever on May 26. The retraction distance is considered the most important retraction slicer setting, and it controls the length of filament that is pulled back by the extruder for every retraction move. 05. Flow Rate: 0. Open and login to the OctoPrint server, and then click the Settings (wrench icon). So the right place for storage is the filament profile, like Orca Slicer handles it. But regardless, the result was impressive without the need for any tinkering from our side. First was to enable ironing on top level for a print. You can also do this after you have gone through some setting changes to test out their effect. stl. Let’s go over the setup process in detail. A good retraction test print is a stringing tower, a simple. 5. But I’d start with the basic max flow rate test. Upload to the printer and print. retract/de-retract filament speeds. However, if one has configured a large retraction in the slicer (eg, 5mm or greater) then one may find they limit the desired speed of retractions. The best way to do it is to set outer wall speed to 30mm/sec leaving the rest at default. 1. In the slicer, you can adjust the retraction speed and distance. How to print just the part, nothing else. twack3r July 3, 2023, 4:25pm 10. BD489 June. /On orcaslicer 1. (which are the default Orca Slicer retraction test parameters) wootsuit July 23, 2023,. It seems to ignore this setting, the first layer speed is respected at 40mm/s though. Orca Tolerance Test Retraction. By adjusting Cura retraction settings, the slicer can adjust the g-code sent to the printer, altering the retraction process in various ways. 3 or Bambu studio 1. 2 layer. The square should be 25 x 25 mm with it's height scaled to match the target layer height. This is represented as a percentage, so enter the value accordingly. What I already did in Orca, is to create a new printer. Step: Direct drive: 0. You can try it @ 35c and see how it’s working. 2mm - 0. 0 mm ; ABS: 0. Cooling and Layer Times. Print the retraction test model. But when I increase the flow rate to increase the quality, the dimension is incorrect. . 3 it has more options and settings. At first, the Bambu Studio and OrcaSlicer won't seem too different from each. Scroll down until you get to the part called "Assets. Once you find a general range, run again with narrower range / finer increment. folder. But as the print is ongoing there seems to be no change of the parameter. Extruder Retraction SuperSlicer retraction 3D printer test [Source: Fabbaloo] Stringing is the curse of 3D printing, and with this test you can very quickly identify the retraction length. Length = 1. I don’t have any partnership(or collaboration) with Bambulab, nor have they sponsored Orca Slicer or me in any way. 91 0. Next step would be retraction calibration I guess. 1. The printer is a Kingroon KP3S with the Titan direct extruder. By anyone’s standards that is one big build area, and we are at odds to disagree. Filament - !!!Dry!!! as others suggested , and filament parameters especially if not using Bambu filament, strongly suggest to use Orca slicer 1. OrcaSlicer takes a great slicer and makes it even better with a few small changes. antodn July 3, 2023, 4:01pm 9. or retraction test and have tried the flow test once and realized it wasn’t worth the effort. Hey guys, Im on my third attempt with this print and its getting frustrating. All the calibration is super simple to use. The setting that you need to enable is called retraction, in this vide. Judging by the pictures, if it's not physical, it's printing too fast or over-extrusion. 7 ( never used this one i use orca slicer) and do flow calibration, advance pressure, Print temperature as an option i do maximum print speed test and retraction test and. 6. Stooovie • 3 mo. Download the Win64 zip file if you're running Windows. G-code generator for 3D printers (Bambu, Prusa, Voron, VzBot, RatRig, Creality, etc. After you've downloaded the file, you need to open it and run the orca-slicer. Retraction Test. 005 increment. List of supported g-code commands. Plus all the issues I had in Cura are now gone. Literally, the only difference between these two shots is in cura. by Gloria E. Stringing after switching to orca slicer. There was Bambu labs and they mention Orca but it seems like the step child of that. 5mm, which basically eliminated stringing on subsequent prints. Tags. Common slicers used with Klipper are Slic3r, Cura, Simplify3D, etc. Maximum Retraction Count – 10. 6. Still have some tuning issues to iron out before I go faster, but the total time will be about 10 hours to complete vs about 14 hours the slicer predicted. Stringing after switching to orca slicer. PETG benefits from a hot nozzle and a warm build plate to get the best results. The Orca can print in layer resolutions as low as 50 microns and. And not by a constant amount or even a constant percentage as distance increases from the center of the build plate, so I can't compensate for it in the slicer, or at least not for more than one dimension on a part. 6. But many of us use Pursa Slicer for some prints. By default, the starting flow is 2, the ending flow is 40, and the flow step is 0. Orca Slicer: All You Need to Know to Get Started. Polymaker TPU: & Slicer Filament Material and Brand Nozzle and Bed Temperature Print Speed Nozzle Retraction Settings Additional settings or relevant information is always encouraged. Download the Win64 zip file if you're running Windows. What 1mm of retraction distance can do. (which are the default Orca Slicer retraction test parameters) EDIT: It occurs to me that maybe you printed a retraction tower test with a fixed retraction value of 2. Dropped the speeds down to 40mm/s. I think some people might have been misled. I was wondering if there is a way to do that in prusa slicer? Or if anyone has a retraction gcode setup to test varying retraction settings in one print? I know I can adjust the setting manually. Set the Maximum Retraction Count to 10 and only adjust if you notice filament damage. Orca Slicer is a fork of Bambu Studio. I put this Redit up because there didn’t seem to be a dedicated Orca Slicer Redit available. 2mm, according to your machine spec extruder settings that you’ve shared, and not one that starts an 0mm on the bottom and ends at 2mm on the top. EDIT: It occurs to me that maybe you printed a retraction tower test with a fixed retraction value of 2. . So, largely the printer just works. Fixed a regression where the bed type was not remembered and switched when changing bed types. . The same clearance to prevent collisions, but with the hope of reduced. 6mm nozzle, what changes did you make in your slicer (I use PrusaSlicer) as compared to a 0. masqcorp May 10, 2023, 7:19pm. So, largely the printer just works. Make sure you are in Expert mode. 1. This seems to be the main calibration that is currently missing from Orca Slicer and the only reason I ever revert back to Cura. 5 mm at 50-60 mm/s. Print test objects to verify the capability of your printer: temp tower, calibration cube, and bridging test, or Bed Level correction tool for advanced users. Keep us updated . 8. 3. PETG: 1,0 mm at 30-40 mm/s. 3. Reduce Printer Noise. The only way I find is to add several extruders, change rectration settings for each one and later change something in the G-code to make one extruder again. cfg. WOW! What a difference. Thanks. This value must be calibrated in any case for the filament used. ” CALC: retraction=0+measured_height x 0. 9. Ironing pattern. Height: Your maximum retraction length will be (height - 1) * step. fresh pla+ dryed 12 hours 45* 28%. I comes. 1 / Tri-ZeroThe best flow rate for the FLSUN Super Racer in Cura: Default value: 100%. Below is a screenshot showing the folder vs whats showing in orca. Howdy! I'm still learning the ins and outs of my Prusa Mini+, and having a lot of fun with it. Retraction settings and flow calibration are the way to fix this. Ellis' generator is itself adapted from a generator developed by Sineos for Marlin, which is licensed under GNU General Public License, version 3. I then also created a new filament profile called “Test” in Orca. . 5. ; The available variables are not always published, however, so you sometimes need to dig around to find the names of them. Use find and replace to find M900 K and replace it with the respective values: Klipper is SET_PRESSURE_ADVANCE ADVANCE=. I recently tried out orcaslicer, and I love a lot of features they have, that Cura doenst have or less accessible. (which are the default Orca Slicer retraction test parameters) wootsuit July 23, 2023, 8:23pm 21. . And I did figure out the Temp Tower in Cura with your help. You may have to make your own calibration tests using Bambu Studio or Orca Slicer and their modifiers. While the stringing can be improved on the test parts, the surface on most real world parts I print got worse by changing the retraction and lift. 8-1. The retraction of the Neptune 3 Plus is 2. Fixed a bug causing "vector too long" issues in some. However, with a high probability, you will still notice some stringing with these settings. Basically, it makes sure that your extruded filament bead stays at a consistent width when sudden changes in speed or directions take place. When I adjust my flow rate so the wall dimension is correct, the quality is terrible and there is definite under extrusion. WOW! What a difference. . Slicers ¶ This document provides some tips for configuring a "slicer" application for use with Klipper. 2 isn't bad. I do not understand what settings I need to adjust in orca slicer. I just changed my X1C from 0. Fighting fine stringing is one of the most frustrating problems to pin down, and our slicers provide numerous work-arounds to help us deal with this problem: retraction and de-retraction length. Luban is useless and it would be great to get Prusa slicer to communicate with the A350. 'Process-3' from 5mm - 5. I was using creality slicer. This set of calibration models was printed with a lower temperature – 205° C, which is a standard PLA printing temperature for about 60 mm/s and a V5/V6 hot end. And in the meantime I get along better with Orca than with Prusaslicer. Orca Slicer 1. ago. I somehow have issues to find a simple tutorial for creating a retraction tower with Prusa slicer. It is pretty easy to use but has 2 main issues. Your bed plate should work. Extruder retraction. 2mm, 0. Filament - !!!Dry!!! as others suggested , and filament parameters especially if not using Bambu filament, strongly suggest to use Orca slicer 1. Did you find a retraction calibration in orca? Looks like it was removed under calibration menu Jumpy_Key6769 • 4 mo. 4mm Z Hop Height for a 0. polymaker petg electric blue. 2. The best retraction settings for the Ender-3 Neo in Cura: PLA: 5 mm at 60 mm/s. Hello SoftFever, is it possible to add the posibility of choosing wheather retract controlled by slicer or by firmware (G10/G11)? I just came from SuperSlicer in combination with klipper driven printers. Well, kind of. Figured Id help out for easy copy and pasting! start_retraction_length + measured_height * step. Download files and build them with your 3D printer, laser cutter, or CNC. EDIT: It occurs to me that maybe you printed a retraction tower test with a fixed retraction value of 2. 6. 8 mm; Retraction Speed. 8 instead of 0. link:Tech Github:cette vidéo, je vous aide à installer Orca Slicer et à paramétrer votre première imprimante. 0 on my Bambu Lab P1P my new project with Timelapse. . This will unlock many more Prusa slicer features like cut, multi layer color. I recently switched over to Orca Slicer. Describe the bug The tower needs two bottom shell layers also it has manifold errors but they will repair. My patron Leo told me about the SoftFever fork of Bambu Studio (now renamed OrcaSlicer), the open source slicer used by Bambu Labs. Feature-packed and a fork of Bambu Studio, Orca Slicer has been gaining ground in the slicer world. log would help since it contains the interpreted config that you are using. Change your temps to match the material. I went through the OrcaSlicer calibration process and did some tuning, but my. Qidi xmax3 wifi problems with Orcaslicer. Incorrect retraction settings in 3D printing can lead to a range of issues that detrimentally affect the final print quality. Creality Slicer and Cura are both slicing software programs that prepare 3D models for printing. 75 mm and a speed of 50 mm/s (for. You switched accounts on another tab or window. You should be looking at around 1-3mm retraction, 20-40mm/s speed. This comprehensive guide will. Typically, Voron 2. Length: 7. Go through the retraction test I posted. File:12 retraction performance test. . Currently using Orca because it has excellent base profiles that need little to no tuning and just some simple adjustments to run on nearly any machine you can think of. This is a custom model and bed texture for the FLSUN Q5. 4. PA Start Value. ago. Likewise, retraction speed changes how fast the. retraction test in to I think that will fix the string #388. Some materials may ooze more than others, and may require increased retraction distance & travel speed to achieve. CTRL-V test print made on the Anycubic Kobra Plus 3D printer. 3mm (This can change for preference but I like the insurance of a little lift if risk of scratching the print) Wipe while retracting: On Retract amount before wipe: 100% (This is suppose to mimics "coasting" from other slicers)I'm a new Orca Slicer user. speed 25mm/s. 2 mm works great. I recently switched over to Orca Slicer. WARNING speeds at the top of the tower set up to 476mms (slower then bambu x1c normal travel speed) so use at your own risk but you have normally stopped the print well before this. (which are the default Orca Slicer retraction test parameters) wootsuit July 23, 2023,. Tuned X1C Print Profiles for Bambu/Orca-Slicer . Retraction Minimum Travel. In Bambu Studio, open the Printer Profile and look under the extruder tab. Thingiverse is a universe of things. 4mm only, so. I'm experimenting with orca using the VFA calibration test it's a great test to see how the ringing is doing for input shaping calibration. if you change it to 0. and the very best slicer I've come across is the Orca Slicer v 1. (which are the default Orca Slicer retraction test parameters)Slice model and look at the g-code where a retraction is happening. Which for a temp tower might be ok, but for nearly anything else really defeats the purpose of tuning your setup. Cheers. I’ve now done the calibration with Orca-Slicer and after the 2 prints I’ve changed the value to 0. 2mm, according to your machine spec extruder settings that you’ve shared, and not one that starts an 0mm on the bottom and ends at 2mm on the top. Filament - !!!Dry!!! as others suggested , and filament parameters especially if not using Bambu filament, strongly suggest to use Orca slicer 1. Set the G-Code flavor to Marlin¶ Many slicers have an option to configure the "G-Code flavor". PanzeeChim. One of the best ways to mitigate oozing and stringing is to adjust Ender 3 retraction settings, which is easy to do using a slicer like Cura. Option to allow to remove flow test from build plate. Alors, nouveau slicer? En fait non, c'est juste un changement de n. 1 Z hop = zero Retraction speed = 40 Deretraction speed = 30 Travel distance = 0. You signed in with another tab or window. 3 Your bed plate should work. Let me. We don't recommend distances greater than 5mm, or less than 0. (which are the default Orca Slicer retraction test parameters) wootsuit July 23, 2023,. ago. If you have. Build Surface Preparation & Handling. 4 nozzle printing ABS - if you don't mind ringing, or have a finely tuned machine with input shaper, 120mm/s+ is not out of the question. The retraction tower is a vertical structure with multiple notches, each printed at a different retraction length.